Labview Serial Terminal Vi
May 19, 2009 I read that USB is the same as RS-232 serial communication just that the USB has a built in USB/RS-232 adapter in it. Please correct me if I am wrong. I tried to establish the communication using Labview's Basic Serial Write and Read vi example however it was not successful. Dec 18, 2017 Serial Communication - Basic Serial Write and Read. This example opens one VISA resource and configures one COM port. It then performs a serial port read, a serial port write, or both based on the options (read or write) that the user selects on the front panel. If both are selected, the VI will first write data, then read data. Aug 13, 2016 Tutorial Page with Source Code Download Link: Blog Link: embeddedlabora. Nov 24, 2018 You can use the LabVIEW example Serial Port Monitor.vi that demonstrates the use of the NI VISA functions to monitor the Serial port. This example can be found in the NI Example Finder in LabVIEW as follows: Select Help»Find Examples»Hardware Input and Output»Serial» Serial Port Monitor.
1. Loopback Test to Verify Hardware Operation
There are three ways to verify the operation of the serial port: LabVIEW, HyperTerminal, and LabWindows/CVI. All perform a loopback test on the serial port by shorting out the Transfer and Receive pins on the cable connected to that port. Step 1 is the description for shorting the pins and is the first step to all three. The LabVIEW procedure is listed below, and both the HyperTerminal and LabWindows/CVI procedures are linked at the end of the page. Use the following procedure if you are using LabVIEW.
Sep 14, 2018 Looking at LabVIEW's serial communication example (NI Example Finder»Hardware Input and Output»Serial»Simple Serial.vi), you will notice that it starts with a VISA Configure Serial Port node. This sets up both the termination character (which defaults to hex 0A ('linefeed')) and the timeout (defaults to 10 seconds). Jul 09, 2012 I want to read data from the serial port, but because I want to use it as terminal I dont know how many bytes are send. (I think I solved that issue with the attached code) My device sends several lines of data but I want to have it presented in a windows line. Owning Palette: Serial VIs and Functions. Requires: Base Development System. Initializes the serial port specified by VISA resource name to the specified settings. Wire data to the VISA resource name input to determine the polymorphic instance to use or manually select the instance. Use the pull-down menu to select an instance of this VI.
- Connect a cable to your serial port. The most common port is a 9-pin or 25-pin (DB-9 or DB-25) RS-232 port. On the cable, short lines 2 and 3. This connects the Transfer line coming out of the computer to the Receive line going in. Once shorted, the top row of the DB-9 cable should look like this: [1 2=3 4 5]. An easy way to short pins 2 and 3 is to use a paper clip. If you have a female RS-232 cable, bend the paper clip and stick the ends in the second and third hole. If you have a male cable, bend the paper clip in a way that you shorten the long loop to the same length as the short loop. Then you can clamp it on the two pins.
On an RS-485 port, voltages are referenced differentially. Therefore, short TXD+ and RXD+ together and then TXD- and RXD- together (pin 4 to 8 and pin 5 to 9 on a DB-9 cable; pin 1 to 5 and pin 2 to 4 on a Combicon connector). Make sure your software is configured in four-wire mode. - For HyperTerminal or LabWindows/CVI, follow the links at the end of the page.
- For LabVIEW, follow the link 'Loopback Test for Serial Port.' This takes you to the Loopback VI in the Example Program Database, which is a part of the Technical Support page. You need to unzip the file. This VI is written in LabVIEW 4.0.1 and will write a string of words out of the serial port and then read them back in. Before running the VI, make sure to set the port channel correctly. In LabVIEW, zero represents the first serial port. [PC: 0 = COM1, 1 = COM2,.. Mac: 0 = Modem, 1 = Printer,.. Sun: 0 = ttya, 1 = ttyb,..]
- If this works correctly and the string of words is read back in, the serial port hardware works. Most serial port communication problems are in the program and concern timing of read/writes calls or configuration of the serial port.
2. Common Problems
Most problems are in the program, not the hardware. Always use example programs as a reference point for ways to wire the diagram panel. Use the sample VIs shipped with LabVIEW under Help>>Search Examples or from the VIs located in the Examples Program Database linked at the end of the page.
Port Referencing: In LabVIEW, ports are numbered starting at zero. Therefore, port 0 in LabVIEW is COM 1 on a PC.
[PC: 0 = COM1, 1= COM2,.. Mac: 0 = Modem, 1 = Printer,.. Sun: 0 = ttya, 1 = ttyb,..]
Timing In Program, Hanging: Many times, a read operation is performed on a port that results in the Serial Port Read VI stopping and waiting or 'hanging.' One way this can happen is if a read operation is done to the port and the program specifies a certain number of bytes that the Serial Port Read VI should get. The Serial Port Read VI was told to get a designated number of bytes; if there are not that many bytes in the serial port receive buffer, it waits until more bytes are written to the serial port. If no more bytes are written to the serial port to complete the operation, the program hangs and waits indefinitely. This can be eliminated by using the Serial Read with TimeOut VI in Help>>Search Examples>>Serial Communication. Another method is to use the Bytes At Serial Port VI to check the port and see how many bytes are in the buffer. Wiring the result as the input for the number of bytes to read ensures that the read operation completes. Looking at the examples under serial communication in LabVIEW is an excellent starting point.
Timing In Program, Incomplete Transfer: A common problem is when a read operation is done on the serial port and it does not get the complete string of information expected. This may happen when you have a read operation happening before the write operation has time to complete. This could be resolved by using a Sequence structure or by using data flow dependency. Using a Sequence structure with the read after the write will make sure the data is completely written first. Using data flow requires a wire to be connected to the read VI after (downstream) the initial write VI.
Instrument's Termination Character: Serial communication can be very tricky when trying to communicate with devices, because the serial port will output exactly as programmed. This means you must know and program the exact sequence of code, including termination characters, to ensure the instrument operates properly. Common problems occur in not using the termination character required by the instrument or by leaving an extra space/character in the instruction string. There is a new standard for communicating with devices in LabVIEW called Virtual Instrument Software Architecture (VISA), a single interface library for controlling VXI, GPIB, RS-232, and other types of instruments. If you are having problems with serial I/O, VISA is a great way to help eliminate termination character errors and make your code reusable and interchangeable between devices in the future.
3. Virtual Instrument Software Architecture (VISA)
Create A Sub Vi Labview
VISA is a single interface library for controlling VXI, GPIB, RS-232, and other types of instruments on all LabVIEW platforms. VISA is a standard endorsed by the VXIplug&play Systems Alliance, which includes more than 35 of the largest instrumentation companies in the industry. The VISA standard unifies the industry to make software interpretable and reusable over time and regardless of instrument I/O operation. Linked below is a page to help with VISA questions. VISA VIs for LabVIEW 4.x are linked at the end of the page.
See Also:
Serial, GPIB, and VXI Communication with Measurement Studio VISA
VISA Examples for LabVIEW 4.1
4. Printing Reports & Error 37
LabVIEW 5.1 for Windows includes Report Generation VIs that allow you to send text to the printer. For an example of how to use the Report Generation VIs, select Help>>Search Examples>>Advanced>>Report Generation. For printing with serial communication and earlier versions of LabVIEW, see the link below.
If the printer is connected to a local parallel port as LPT1 (or LPT2, etc.), you can use the Serial Port Write VI. For more information, see the Serial Port VIs chapter in your LabVIEW documentation.
If the printer is a network printer, you cannot use the Serial Port Write VI; you must use other methods to print, such as one of the following:
- Use Programmatic Printing of a subVI to programmatically print a string. Select Print VI When VI Completes Execution in VI Setup of the subVI.
- Use the System Exec VI to print a string programmatically by using Notepad.exe. The string to use in the System Exec VI could be: Notepad.exe /p c:junk.txt, where junk.txt is the name of an ASCII text file containing the text to be printed.
For problems with Error 37, follow the link below to check the settings in the labview.ini file.
Watch the latest Episodes Online of Dragon Ball Super, Dubbed in English.Free DBS Episode.Dragon Ball Super is the newest anime series based on the franchise and the first Dragon Ball anime with an original story in 18 years. It’s an official sequel to Z with Toriyama involved in production, and its early episodes cover the events of the films Battle of the Gods and Resurrection F. Is Dragon Ball Super on Netflix?Unfortunately no, Netflix will not be showing Dragon Ball Super in the US or any other country for that matter. Dragon ball z all full episode english. Thanks to a partnership between Crunchyroll and Funimation, the English sub is widely available.
See Also:
Error 37 and writing to the Parallel Port with LabVIEW
5. Modem Communication in LabVIEW
Companies in the Alliance Program support modem communication in LabVIEW very well. National Instruments recommends these companies because of their quality work.
See Also:
Alliance Program
6. User Support Newsgroups
Labview Vi Reader
The Developer Exchange newsgroups are Usenet newsgroups covering National Instruments products, as well as general fields of science and engineering. You can read, search, and post to the newsgroups to share solutions and find additional support from other users. Past questions and solutions are also stored at this site for search purposes.
7. Advanced Troubleshooting of COM Port Data
Advanced users who want to analyze the exact bits being transferred over the serial port to detect differences between programs (for example, LabVIEW vs. HyperTerminal) can use a program called Portmon. System Internals provides Portmon, and the company's Web site provides you advanced utilities, technical information, and source code related to Windows 9x and Windows NT/2K internals.
Labview Vi Download
See Also:
System Internals for Portmon
Labview Serial Terminal Victoria
Related Links:
Testing Serial Communication using HyperTerminal
Testing Serial Communication using CVI
Loopback Test for Serial Port
Using the VISA classes in Measurement Studio to Perform Serial Communication