Console Into Netapp Fas2040

 

How to connect to a NetApp system console serial port from another host

  1. Netapp Console Port
  2. Netapp Fas2040 Manual
  3. Netapp Fas2040 Setup

(On the back of our FAS2040 we have 4 gigethernet ports named e0a, e0b, e0c, e0d. You have the option of bundling 2 or more of these to create an etherchannel to your switch. This becomes beneficial if you are considering running iscsi, nfs or cifs as the traffic can be load balanced across the bundled ports. The RJ45 connector is for serial connection you should have a rj45 to serial cable which you connect and install each controller. Run 'setup' once done you can login use http via filerview or install netapp.

The console port on NetApp storage appliances allow access for configuration and troubleshooting. It allows access to the filer independent of network connectivity. To connect to the console, a console cable is required. The pinout for a console cable for use with the C1200, C2100 RJ45 and all NetApp storage systems and NearStore appliance is as follows:

RJ-45 --> DB9(F)
Pin Color Pin Signal
------ -------- ------- ---------
1 blue 7 RTS
2 orange 4 DTR
3 black 3 TXD
4 red 5 GND
5 green 9 RI
6 yellow 2 RXD
7 brown 6 DSR
8 white 8 CTS

It allows access to the filer independent of network connectivity. To connect to the console, a console cable is required. The pinout for a console cable for use with the C1200, C2100 RJ45 and all NetApp storage systems and NearStore appliance is as follows: RJ-45 - DB9(F) Pin Color Pin Signal- -.

Serial connection settings:
Speed: 9600
Databits: 8
Stop bits: 1
Parity: None
Flow control: Hardware or none

Host Configuration

I. For a Sun Host
  1. Edit /etc/remote by typing vi /etc/remote. Add the following lines:
    filername:
    dv=/dev/ttyb:br#9600:el=^C^S^Q^U^D:ie=%$:oe=^D:

    Note: Use either ttyb or ttya (whichever port the serial cable is connected to).

  2. Type eeprom grep tty grep mode.
    The ports ttya and ttyb should be set as follows:
    ttya-mode=9600,8,n,1,-
    ttyb-mode=9600,8,n,1,-
  3. Open a shelltool, xterm, or dtterm.
  4. Type tip filername. A password prompt should appear. Use Ctrl-d and then ~ to exit.
II. For an HP Host
  1. Edit /etc/uucp/Devices by typing vi /etc/uucp/Devices. Add the following line:
    filername tty0p0 - 9600 direct
  2. Edit /etc/uucp/Systems by typing vi /etc/uucp/Systems. Add the following line:
    filername 9600 filername 9600
  3. Open an xterm or dtterm.
  4. Type cu filername. A password prompt should appear.
  5. Exit using Ctrl-d and then ~ .
  6. Make sure to match the VT100 emulation between the storage system and the HP host.
Note: If you are unable to view the entire content of this article please log in to kb.netapp.com
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

First things first, before getting started you need to create yourself a login at the Netapp NOW website http://now.netapp.com It usally takes 24-48 hours for your login to become active. The NOW website is where you get access to all the documentation, knowledge base, articles, software, licenses, etc

This is obviously not true since my dxdiag is showing 10. I've been trying this for like 2 hours now and I'm so frustrated. I have tried multiple times to download DX11 and whenI run the program to search for updates for it, it says my Direct X is up to date. Directx 11 download windows 10 64 bit online installer. I've researched online and after doing the dxdiag command, it says I have Direct X 10. How can I get 11??

Mixmeister It gives you the power to unleash your creativity and shape your music in a million ways, with live looping and remixing, VST effects, harmonic mixing and more.You can manipulate tempo, volume, and EQ in real time, on-the-fly. You get the functionality of a loop editor or digital audio workstation, but you can blend songs together to create stunning DJ performances.MixMeister Fusion frees you from monotonous tasks like beat matching, setting cue points, and counting beats in your head. It even records all your actions (not just the resulting audio), so you can go back, listen to your mix, and make precise adjustments with studio-style editing capabilities.Fusion's live performance capabilities can be expanded via connectivity with MIDI hardware controllers. Version 7.2 includes breakthrough new features like an enhanced timeline, improved time-stretching and support for Mac OS X.MixMeister Fusion doesn't limit you to simply combining a few loops and grooves together; Fusion is designed to mix complete DJ sets from full-length songs.

Fas2040 manual

Once you’ve racked and cabled your Netapp SAN, according to the documentation on your SAN model you’re ready to start configuring.

Connect the supplied console cable to your pc and start your favourite terminal emulation program. I mainly use Putty which can be downloaded from here http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html

As you power on the SAN it will go through all the POST tests and finally arrive at the setup wizard prompt

Console Into Netapp Fas2040

Netapp Console Port

1. Enter the new hostname (Tip: When Netapp support refer to your controllers, they refer to them as top or bottom. To make it simple try and name and controller at the top something ending in top and for the bottom, something ending in bot. You don’t need to do this but it is less confusing later on down the track)

2a. Do you want to configure interface groups ? (On the back of our FAS2040 we have 4 gigethernet ports named e0a, e0b, e0c, e0d. You have the option of bundling 2 or more of these to create an etherchannel to your switch. This becomes beneficial if you are considering running iscsi, nfs or cifs as the traffic can be load balanced across the bundled ports. Within an interface group you can also create vlans to segment traffic, however I’ll touch on this a little later on. You don’t need to create an interface group, you can answer no here and configure a single port)

2b. If you answered yes to interface groups you are asked the following:

  • Number of interface groups to configure
  • Name of interface group (usually you would name it vif0 which stands for Virtual Interface)
  • Is the interface_group_name a single [s], multi [m] or a lacp [l] interface group (If you are connecting back to cisco switches you would use lacp, though check with your switch vendor)
  • Number of links for interface_group_name (How many physical ports do you want to include in the interface group)
  • Name of link for interface_group_name (For example e0a, e0b, e0c, e0d)
  • IP address for interface_group_name
  • Netmask for interface_group_name
  • Should interface group interface_group_name take over a partner interface group during failover ? (You would answer yes here if you are running redundant controllers and then enter in the second controllers interface name. These names would be identical on each controller)
  • Media type for interface_group_name (If you are running 1 GB you can select auto)

2c. If you did not decide to create an interface group you will pretty much go through the same steps as above minus adding interfaces into a group. Additional options are enabling flow control and Jumbo frames, which if you are running a network protocol such as iscsi, nfs, cifs, etc you will definately enable.

3. You now have the option to continue setting up via the web interface or through the cli. We will continue through the cli

4. Please enter the name or ip address of the default gateway.

5. Please enter the name or ip address for aadministrative host. The administration host is given root access to the storage system’s /etc files for system administration. To allow /etc root access to all NFS clients enter RETURN below. (I would highly recommend entering in an ip address here, such as your management station so that only it has access to the root. This is achievable by enabling CIFS and browsing directly to the storage filer’s root)

6. Please enter timezone (GMT is the default, please refer to the setup.pdf documentation in the Resource area of this site)

7. Where is the filer located ? (This is SNMP location information)

8. What language will be used for multiprotocol files ? (en for english otherwise refer to the setup.pdf documentation in the Resource area of this site)

9. Enter the root directory for HTTP files (Files that are served through HTTP or HTTPS)

10. Do you want to run DNS resolver ? (Basically do you want to storage system to resolve DNS, select yes)

11. Do you want to run NIS client ?

12. Would you like to configure the BMC LAN interface ? (only if you have a BMC installed in your system)

13. Would you like to configure the RLM LAN interface ? (only if you have an RLM installed in your system)

14. Do you want to configure the Shelf Alternate Control Path Management interface for SAS shelves ? (Only if you have DS4243 shelves in your stack. The ACP should be cabled according to the DS4243 install guide, see the Resource section)

15. Setting the administrative (root) password for your filer ? (Enter the password and re-enter to confirm) and reboot.

16. If you are configuring the controllers for an active/active pair, repeat the same steps for the other controller.

Netapp Fas2040 Manual

17. Once the filer has rebooted you can access the web admin page type at https://<ip address>/na_admin

Netapp Fas2040 Setup

Disclaimer:
All the tutorials included on this site are performed in a lab environment to simulate a real world production scenario. As everything is done to provide the most accurate steps to date, we take no responsibility if you implement any of these steps in a production environment.